Marginal integrity of restorations produced with a model composite based on polyhedral oligomeric silsesquioxane (POSS)

Authors

  • Luciano Ribeiro CORREA NETTO Universidade Federal Fluminense; Faculdade de Odontologia; Laboratório Analítico de Biomateriais Restauradores
  • Alexandre Luiz Souto BORGES Universidade Estadual Paulista; Departamento de Materiais Odontológicos e Prótese
  • Heloisa Bailly GUIMARÃES Universidade Federal Fluminense; Faculdade de Odontologia; Laboratório Analítico de Biomateriais Restauradores
  • Elis Regina Nunes de ALMEIDA Universidade Federal Fluminense; Faculdade de Odontologia; Laboratório Analítico de Biomateriais Restauradores
  • Laiza Tatiana POSKUS Universidade Federal Fluminense; Faculdade de Odontologia; Laboratório Analítico de Biomateriais Restauradores
  • Eduardo Moreira da SILVA Universidade Federal Fluminense; Faculdade de Odontologia; Laboratório Analítico de Biomateriais Restauradores

DOI:

https://doi.org/10.1590/1678-775720150041

Abstract

Marginal integrity is one of the most crucial aspects involved in the clinical longevity of resin composite restorations.Objective To analyze the marginal integrity of restorations produced with a model composite based on polyhedral oligomeric silsesquioxane (POSS).Material and Methods A base composite (B) was produced with an organic matrix with UDMA/TEGDMA and 70 wt.% of barium borosilicate glass particles. To produce the model composite, 25 wt.% of UDMA were replaced by POSS (P25). The composites P90 and TPH3 (TP3) were used as positive and negative controls, respectively. Marginal integrity (%MI) was analyzed in bonded class I cavities. The volumetric polymerization shrinkage (%VS) and the polymerization shrinkage stress (Pss - MPa) were also evaluated.Results The values for %MI were as follows: P90 (100%) = TP3 (98.3%) = B (96.9%) >; P25 (93.2%), (p<0.05). The %VS ranged from 1.4% (P90) to 4.9% (P25), while Pss ranged from 2.3 MPa (P90) to 3.9 MPa (B). For both properties, the composite P25 presented the worst results (4.9% and 3.6 MPa). Linear regression analysis showed a strong positive correlation between %VS and Pss (r=0.97), whereas the correlation between Pss and %MI was found to be moderate (r=0.76).Conclusions The addition of 25 wt.% of POSS in methacrylate organic matrix did not improve the marginal integrity of class I restorations. Filtek P90 showed lower polymerization shrinkage and shrinkage stress when compared to the experimental and commercial methacrylate composite.

Downloads

Download data is not yet available.

Downloads

Published

2015-10-01

Issue

Section

Original Articles

How to Cite

Marginal integrity of restorations produced with a model composite based on polyhedral oligomeric silsesquioxane (POSS) . (2015). Journal of Applied Oral Science, 23(5), 450-458. https://doi.org/10.1590/1678-775720150041